UGR
Unified Glare Rating
This is an approximate model expressing the risk of glare.
The standard values range from UGR 16 (low risk of glare) to UGR 28.
In the standard for workplace lighting EN12464-1, limit values for UGR are imposed for various rooms.
Typical UGR values :
- Office/Classrooms/Meeting rooms : UGR<19
- Corridors : UGR<28
- Staircases : UGR<25
- Warehouses : UGR<25
Flux (lm)
Light distribution
Line concept
Individual luminaires are individually mounted and connected.
It is also possible to connect luminaires together for in-line mounting, whereby the luminaires are mechanically and electrically connected.
E4 and E7: in-line luminaires are interchangeable, and additional headpieces must be placed at the start and end of the line.
E5 and R3: There are unique luminaires for the ends and the middle of a line.
R7: There are unique luminaires for the beginning, middle and end of the line.
Connection type
Luminous efficacy (lm/W)
DUMAVA Subsidie
Led-verlichtingsarmaturen met een uitwisselbare led-lichtbron en met een specifieke lichtstroom van ten minste 125 lm/W komen in aanmerking voor de DUMAVA subsidie.
E7
E7 combines the lighting comfort of LED+LENS™ technology with a robust, yet elegant industrial housing. This way, you can illuminate sports halls and high production halls with maximum visual comfort and high efficiency. All luminaires are impact resistant (IK08) and ballproof (DIN 18032-3). E7 is available as a light line or as an individual luminaire.
20 variants found